DESTAQUES
 
 
 
 
 
 
 
 
 
 
ABFM NEWS - Radioterapia
 
“radiation oncology physicist” should be changed to “oncologic physicist”
 
"Some years ago, physicians who practiced radiotherapy changed their appellation from “radiation therapists” to “radiation oncologists.” This led radiotherapy technologists to seize the opportunity to change their name to “radiation therapists.” It has been suggested that maybe radiation oncology physicists are in need of a change of title, possibly to “oncologic physicists.” This is the proposition debated in this month’s Point/Counterpoint." [+ leia mais]
Fonte: Medical Physics
 
 
Inhibitory effect of radiotherapy combined with weekly recombinant human endostatin on the human pulmonary adenocarcinoma A549 xenografts in nude mice
 
"Abstract The aim of this study was to investigate the inhibitory effect of radiotherapy combined with weekly recombinant human endostatin (RHES) on the human pulmonary adenocarcinoma A549 xenografts in nude mice. The 40 A549 xenograft nude mice models were randomly divided into 4 groups (each group with 10 nude mice). Single radiotherapy group (group 1) was given a single external irradiation (6MV-X ray, 10 Gy) and peritumoral subcutaneous injection of 0.2ml normal saline every day for 7 days. Single RHES group (group 2) was given peritumoral subcutaneous injection of 0.2ml RHES (0.75mg/ml) for 7 days. Combination therapy group (group 3) was given radiotherapy as the same as group 1 and RHES as the same as group 2. Control group was given normal saline as the same as group 1. The tumor volume was smaller in group 3 than in control group from the 8th day after treatment (P<0.05) and tumor regression occurred from the second week after treatment in group 3. On the 15th day after treatment, the inhibitory rates of tumor volume were 69.65%, 92.64% and 116.4% in groups 2, 1 and 3, respectively; MVD number was lower in group 3 than in group 1 (P<0.05); there was no statistical significance in VEGF expression between group 2 and control group as well as between group 3 and group 1 (P>0.05). Apoptosis was marked in group 3. Radiotherapy combined with weekly RHES can significantly inhibit tumor growth and earlier induce tumor regression, which may be related to the improvement of tumor hypoxia and the inhibition of radiation-induced tumor angiogenesis. Short-term application (1 week) of RHES is beneficial to clinical practice. " [+ leia mais]
Fonte: Lung Cancer
 
 
Diagnosis and treatment of esthesioneuroblastoma in the nasal cavity and sinuses
 
"Abstract OBJECTIVE: To discuss the clinical characteristics, diagnosis and treatment of esthesioneuroblastoma (ENB). METHODS: The clinical data of 7 patients with ENB were analyzed retrospectively, and the clinical characteristics, diagnosis, surgical approaches and prognosis of the disease were discussed. RESULTS: The 7 patients received surgical treatment combined with radiotherapy and chemotherapy. Tumor relapse occurred within one year in two cases, which were treated with a second operation combined with radiotherapy, and one patient died and one survived with tumor after a one-year follow-up. CONCLUISON: Early diagnosis of ENB can be difficult. Transnasal-frontal approach with nasal endoscope is effective approach to ENB treatment, and the patients may benefit from postoperative radiotherapy and chemotherapy to improve the prognosis. " [+ leia mais]
Fonte: Nan fang yi ke da xue xue bao = Journal of Souther
 
 
Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verific
 
"Abstract The purpose of this work is to provide guidelines for the routine use of portal dosimetry and in vivo diode measurements to verify intensity-modulated radiotherapy (IMRT) treatments. To achieve tolerance levels that are sensitive enough to intercept problems, both the portal dosimetry and the in vivo procedure must be optimised. Portal dosimetry was improved by the introduction of an optimised two-dimensional (2D) profile correction, which also accounted for the effect of backscatter from the R-arm. The scaled score, indicating the fraction of points not meeting the desired gamma evaluation criteria within the field opening, was determined as the parameter of interest. Using gamma criteria of a 3% dose difference and 3 mm distance to agreement, a ""scaled score"" threshold value of 1.5% was chosen to indicate excessive tongue and groove and other problems. The pre-treatment portal dosimetry quality assurance (QA) does not encompass verification of the patient dose calculation or position, and so it is complemented by in vivo diode measurements. Diode positioning is crucial in IMRT, and so we describe a method for diode positioning at any suitable point. We achieved 95% of IMRT field measurements within ±5% and 99% within ±8%, with improved accuracy being achieved over time owing to better positioning. Although the careful preparation and setup of the diode measurements can be time-consuming, this is compensated for by the time efficiency of the optimised procedure. Both methods are now easily absorbed into the routine work of the department. PMID: 20965905 [PubMed - in process] " [+ leia mais]
Fonte: The British Journal of Radiology
 
 
Detecção de câncer de testículo em homens com infertilidade.
 
"PROPÓSITO: Infertilidade é um dos padrões incomuns associados com tumores de testículo. Nós avaliamos os achados histológicos, bioquímicos, e gravidez em pacientes com infertilidade nos quais foram detectados tumores de testículo. MÉTODOS: Sete pacientes com infertilidade nos quais câncer de testículo foi detectado em um período acima de 15 anos. Todos os pacientes foram avaliados com ultra-sonografia. As indicações para ultra-sonografia foram dor testicular em dois pacientes, suspeita de massa palpável em quatro, e descartar a presença de neoplasia de células germinativas em um paciente com carcinoma in situ detectado em biópsia prévia. Exame físico, achados histológicos, níveis hormonais, marcadores tumorais, e resultados de gravidez foram avaliados nos prontuários dos pacientes. RESULTADOS: Dois homens tinham níveis séricos elevados de hormônio folículo-estimulante e hormônio luteinizante; um destes tinha níveis anormalmente baixos de testosterona. Marcadores tumorais estavam normais em todos os pacientes. Em quatro pacientes, o tumor estava localizado no testículo direito e em três no esquerdo. Os diagnósticos histológicos foram seminoma (n = 5), tumor de células de Leydig (n = 1) e carcinoma in situ (n = 1). Dos sete pacientes, cinco foram submetidos à radioterapia. Dois pacientes congelaram seus espermatozóides. Acompanhamento no estado de fertilidade estava disponível em seis pacientes. Um paciente estabeleceu gravidez e cinco não conseguiram engravidar após tratamento do câncer. CONCLUSÕES: A maioria dos homens com câncer de testículo e infertilidade possui um seminoma. Homens que se apresentam com infertilidade devem ser cuidadosamente investigados para descartar doenças concomitantes e sérias juntamente com a infertilidade. " [+ leia mais]
Fonte: Revista do Hospital das Clínicas
 
 
Reprodutibilidade de posicionamento em radioterapia
 
"A evolução tecnológica ocorrida nos campos da robótica e da informática proporcionou avanços importantes na radioterapia, permitindo que se administrem doses cada vez mais altas no alvo tumoral mantendo-se baixos níveis de complicações nos tecidos sadios vizinhos. Os planejamentos informatizados se beneficiaram desta evolução e hoje permitem a fusão de diferentes modalidades de imagem, tais como, tomografia computadorizada, ressonância magnética e tomografia por emissão de pósitrons, para uma melhor definição dos volumes alvos e órgãos de risco(1). Houve um aumento global da precisão em todas as etapas do processo de tratamento radioterápico, desde o planejamento até a administração precisa dos feixes. Com isso, permite-se a utilização de esquemas de tratamento em única sessão ou poucas sessões, enquanto tradicionalmente se realizam entre 10 e 40 sessões. " [+ leia mais]
Colaborador: Laura Natal
Fonte: Radiol Bras vol.43 no.4 São Paulo jul./ago. 2010
 
 
FIVE YEAR RESULTS OF LINAC RADIOSURGERY FOR ARTERIOVENOUS
 
"The obliteration rates for treatment volumes < 4 cc, 4–13.9 cc, and > 14 cc were 67%, 58%, and 23%, respectively. AVM obliteration was significantly associated with higher minimum treatment dose and negatively associated with a history of prior embolization with particulate materials. No AVM receiving < 1400 cGy was obliterated. The incidence of post-radiosurgical imaging abnormalities and clinical complications rose with increasing treatment volume. For treatment volumes > 14 cc receiving > 1600 cGy, the incidence of postradiosurgical MRI T2 abnormalities was 72% and the incidence of radiation necrosis requiring resection was 22%. The rate of post-radiosurgical hemorrhage was 2.7% per person-year for AVMs with treatment volumes < 14 cc and 7.5% per person-year for AVMs > 14 cc. Conclusion: As AVM size increases, the dose-volume range for the optimal balance between successful obliteration and the risk of complications and post-radiosurgical hemorrhage narrows. © 1999 Elsevier Science Inc." [+ leia mais]
Colaborador: Marco Antonio
Fonte: Int. J. Radiation Oncology Biol. Phys., Vol. 44, N
 
 
Radioterapia estereotáxica fraccionada en adenomas de hipófisis: resultados y factores pronósticos
 
"Con un seguimiento de 51 meses (9–102 meses), al cierre del estudio, 49 pacientes están vivos sin evidencia de enfermedad, una paciente viva, con pérdida de visión y progresión hormonal, 2 pacientes han fallecido con progresión y uno falleció por otra causa. La supervivencia global fue de 94% (50/53), con una supervivencia libre de fallo del 92% (49/53). En análisis univariado sólo el tipo de hormona secretada (ACTH) y la irradiación previa resultaron de mal pronóstico. Catorce pacientes (25%) presentaron síntomas leves de toxicidad aguda durante la radioterapia estereotáxica fraccionada y 3 (5,4%) desarrollaron toxicidad tardía, neuropatía óptica (2 pacientes, multipatología asociada) y radionecrosis (1 paciente, reirradiación). Conclusiones " [+ leia mais]
Colaborador: Marco Antonio
Fonte: Clinical and Translational Oncology
 
 
Avaliacao de Streptococcus Nutans e Velocidade do Fluxo Salivar em Pacientes com Cancer de Cabeca e Pescoco Submetidos a Quimioterapia e Radioterapia.
 
"Foi realizado um estudo quantitativo, observacional e transversal, por meio de análise da saliva sob dois aspectos: fluxo e microbiologia. A amostra foi constituída por nove pacientes com câncer de cabeça e pescoço tratados na Fundação Assistencial da Paraíba/FAP no município de Campina Grande/PB, Brasil. O método de coleta de saliva foi não estimulada, adotando para hipofunção salivar o valor de 0.1ml/min. A contagem de Streptococcus mutans foi determinada por UFC/ml. A associação entre as variáveis foi verificada pelo teste do Qui-Quadrado de Pearson (p<0,05). Conclusão: Após a radioterapia e quimioterapia ocorreu a diminuição do fluxo salivar e aumento do número de Streptococos mutans. O fato de que 100% dos pacientes não tiveram acompanhamento odontológico demonstra a importância de medidas odontológicas profiláticas, prévias ao tratamento oncológico." [+ leia mais]
Colaborador: Marco Antonio
Fonte: Pesquisa Brasileira em Odontopediatria e Clínica
 
 
Verificação dosimétrica de tratamentos de IMRT utilizando câmara de ionização, filme radiográfico e função gama
 
"Resumo Este trabalho teve por objetivo avaliar o método adotado para o controle de qualidade de planejamentos de radioterapia com intensidade modulada do feixe (IMRT) por meio da verificação das distribuições de dose medidas e planejadas, analisando a concordância dos resultados com os critérios de aceitação previamente estabelecidos." [+ leia mais]
Fonte: RBFM
 
 
Estudo da atenuação do feixe de 6MV em tratamentos radioterápicos de mama pós-mastectomia devido à heterogeneidade metálica de expansores de tecido
 
"Resumo Neste trabalho foi estudada a alteração da atenuação do feixe de 6MV utilizado em tratamentos radioterápicos devido à heterogeneidade metálica presente em alguns tipos de expansores de tecido, usados no processo de reconstrução mamária." [+ leia mais]
Fonte: RBFM
 
 
Avaliação dosimétrica de um detector microMOSFET
 
"Resumo Este trabalho teve como objetivo caracterizar um dosímetro mMOSFET em feixe de fótons de alta energia por meio da avaliação dos parâmetros de desempenho, tais como: estabilidade; linearidade com a dose; dependência com a taxa de dose, dependência energética; distância fonte-detector e fator campo." [+ leia mais]
Fonte: RBFM
 
 
Direct measurement of instantaneous source speed for a HDR brachytherapy unit using an optical fiber based detector
 
Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. [+ leia mais]
Fonte: Medical Physics
 
 
Europeu crê menos na ciência, diz estudo
 
Enquete realizada pela "Nature" mostra desconfiança do público em temas como H1N1 e energia nuclear na União Europeia [+ leia mais]
Fonte: Jornal da Ciência
 
 
Apparent absence of a proton beam dose rate effect and possible differences in RBE between Bragg peak and plateau
 
Purpose: Respiration-gated irradiation for a moving target requires a longer time to deliver single fraction in proton radiotherapy (PRT). [+ leia mais]
Fonte: Medical Physics
 
 
Advanced treatment planning methods for efficient radiation therapy with laser accelerated proton and ion beams
 
Purpose: Laser plasma acceleration can potentially replace large and expensive cyclotrons or synchrotrons for radiotherapy with protons and ions. [+ leia mais]
Fonte: Medical Physics
 
 
Monte Carlo simulation of the effect of miniphantom on in-air output rat
 
Purpose: The aim of the study was to quantify the effect of miniphantoms on in-air output ratio measurements, i.e., to determine correction factors for in-air output ratio [+ leia mais]
Fonte: Medical Physics
 
 
Monte Carlo characterization of skin doses in 6 MV transverse field MRI-linac systems: Effect of field size, surface orientation, magnetic field stren
 
Purpose: The main focus of this work is to continue investigations into the Monte Carlo predicted skin doses seen in MRI-guided radiotherapy. [+ leia mais]
Fonte: Medical Physics
 
 
Feasibility Study for Markerless Tracking of Lung Tumors in Stereotactic Body Radiotherapy
 
"Purpose To evaluate the feasibility and accuracy of a method for markerless tracking of lung tumors in electronic portal imaging device (EPID) movies and to analyze intra- and interfractional variations in tumor motion. " [+ leia mais]
Fonte: Int J of Radiation Oncology, Biology and Physics
 
 
Respiratory Organ Motion and Dosimetric Impact on Breast and Nodal Irradiation
 
"Purpose To examine the respiratory motion for target and normal structures during whole breast and nodal irradiation and the resulting dosimetric impact. Methods and Materials " [+ leia mais]
Fonte: Int J of Radiation Oncology, Biology and Physics
 
 